Pressure Gauges For Severe Applications

Instruments of this series are manufactured for all those applications where it's needed a very accurate and strong execution, to allow a steady and long term reliability.

Pressure Gauges For Severe Applications

Pressure Gauges For Severe Applications

Pressure Gauges For Severe Applications

Pressure Gauges For Severe Applications

Pressure Gauges For Severe Applications
Pressure Gauges For Severe Applications
    • Pressure Gauges For Severe Applications

    • Instruments of this series are manufactured for all those applications where it's needed a very accurate and strong execution, to allow a steady and long term reliability.

About Us Pressure Gauges For Severe Applications

  • Overview
  • Specification
  • Documents

Overviews

   
     
 

      Instruments of this series are manufactured for all those applications where it’s needed a very accurate and strong execution, to allow a steady and long term reliability. Pressure gauges of SP 300 series are suitable for specific requirements, such as electric contacts, customized executions, Monel manometric element or moreover as described below.
      The traditional series SP 300 is supported by series SP 200, that maintain the 
well-known quality level, but allow a considerable economic advantage, due to mass production with advanced technology.

 

   

Features

   
     
   
  • Stainless Steel Tube Or Mone
   
  • Watertight Casing, Dry Or Liquid Filled Execution
   
  • NS 100 - 150 - 200 - 260
   
  • Ranges Included Between -1 And 1600 Bar

Specifications

   
     

Nominal sizes

 

100, 150, 200 and 260

Casing

 

Execution B:

+Case and ring in AISI 304 stainless steel (AISI 316 on request for NS 100 and 150 - option V61) with bayonet bezel;

Execution A:

+Aluminium case and ring NS 260 painted with black epoxy powder with screw clamping.

Protection degree

 

- IP 55 for execution D (dry);

- IP 65 for execution F (liquid filled) and for execution P (fillable).

Window

 

- Glass for dry execution;

- Methacrylate for liquid filled and fillable executions;

- Laminated safety glass (on request - option V17).

Blow-out device

 

- Nlow out plug for NS 100, 150 and 200;

- Rubber plug for execution D (dry) for NS 260;

- Calibrated valve for execution F (liquid filled) and for execution P (fillable) for NS 260.

Filling liquid

 

- Glycerine (standard);

- Silicone fluid, standard if the instrument is provided with electrical contact or, on request, as alternative to glycerine - option V64;

- Special fluids (on request).

Pressure connection

 

G 1/2 B (1/2 Gas or BSP) or 1/2-14 NPT EXT (1/2 NPT) thread (others on request);

- AISI 316L stainless steel (execution 2);

- Monel (option V68).

Pressure element

 

- AISI 316Ti stainless steel (execution 2);

- Monel (option V68).

Movement

 

- Stainless steel.

Maximum values

 

- 1600 bar for NS 100 and 150;

- 1000 bar for NS 200 and 260.

Unit of pressure

 

- Bar, kPa, MPa, kg/cm2 and psi for single or double range.

Scale angle

 

- 270°.

Working pressures

 

- Steady from 1/10 to 3/4;

- Fluctuating from 1/10 to 2/3;

- Pulsating from 1/10 to 1/2.

Over-pressures

 

- 130% of full scale value (standard);

- 160% of full scale value (option V25);

- 250% of full scale value (option V27);

- For others over-pressure values use over-pressure protectors (see AM series).

Pointer

 

- Aluminum with micrometer adjustment for dry execution and for execution with electric contacts;

- Aluminum not adjustable for liquid filled execution.

note: if the instrument is class 0,6 the pointer is knife edged.

Dial

 

- White aluminium with black figures (for dial modifications see available options).

Accuracy

 

- Class 1 (± 1% of full scale deflection) standard;

- Class 0,6 (± 0,6% of full scale deflection) optional option V36 (for BS and ANSI class 0,6 becomes ± 0,5% f.s.d.).

Ambient temperature

 

- -30 ÷ +60 °C dry execution;

- +10 ÷ +60 °C glycerine filled execution;

- -30 ÷ +60 °C silicone fluid filled execution.

Thermal drift

 

- Out of optimum ambient temperature values included within +15 ÷ +25°C, the thermal drift affects the instruments accuracy of 0,3% every 10°C.

News

News

Bao Nghi Techniques Service Trading Company limited.
15/09/2017
Copyright © 2017 Bao Nghi. All rights reserved. Designed by Nina.vn
GỌI