    • DeltaV™ S-series Electronic Marshalling delivers a new level of control system I/O performance with unprecedented flexibility and ease of use. The CHARM I/O card (CIOC) supports up to 96 individually configurable channels and is designed specifically for multi-core home run cables in centrally located marshalling cabinets. It can also be installed in field junction boxes to further reduce system design and installation costs.

About Us DeltaV™ S-series Electronic Marshalling

  • Overview
  • Specification
  • Documents

Overviews

   
     
 

DeltaV™ S-series Electronic Marshalling delivers a new level of control system I/O performance with unprecedented flexibility and ease of use. The CHARM I/O card (CIOC) supports up to 96 individually configurable channels and is designed specifically for multi-core home run cables in centrally located marshalling cabinets. It can also be installed in field junction boxes to further reduce system design and installation costs. All communications are completely redundant from the channel (CHARM) to the DeltaV S-series controller.

   

Features

   
     
   
  • DeltaV™ CIOC provides an unprecedented flexibility in control system I/O topology
   
  • CHARM I/O architecture allows each individual channel to be characterized for the requirements of the field device
   
  • Helps reduce overall system costs by eliminating internal cabinet cross wiring, reducing overall footprint, simplifying I/O channel assignments, and reducing Factory Authorized Testing activities

 

 

  • CIOC architecture is fully redundant

 

 

  • All components of the CIOC are rated for installation in Class 1/Div 2 or Zone 2 hazardous locations

 

 

  • Designed for ease of use, both in physical installation and its software tools

Specifications

   
     

Operating Temperature

 

-40 to 70° C (-40 to 158° F)

Storage Temperature

 

-40 to 85° C (-40 to 185° F)

Relative humidity

 

5 to 95%, non-condensing

Shock

 

10 g½-sine wave for 11 ms

Vibration

 

1 mm peak-to-peak from 5 Hz to 16 Hz, 0.5 g from 16 Hz to 150 Hz

Electronic Marshalling hardware

 

  • CHARM I/O Carrier (DIN rail-mounted and supports redundant pair of CHARM I/O Cards, redundant 24 V DC power connectivity, and redundant Ethernet communication modules).
  • CHARM I/O Card (provides communication between CHARMs and the Ethernet I/O network to S-series controllers).
  • CHARM Base plate (DIN rail-mounted with interleaving power and bus connectors. Supports 12 CHARMs and their terminal blocks, as well as connection for injected field power).
  • CHARM Terminal Block (removable terminal block providing terminal connections to field wiring and physical latch for CHARM).
  • CHARMs (Characterization Module for each field signal. Provides basic analog to digital conversion and signal isolation to the redundant communication bus).
  • Cable Extenders that provide flexibility in carrier mounting.
  • I/O bus termination (provides bus terminations for redundant I/O bus).
  • Labeling features for baseplate and channel identification

Charm types

 

  • AI 4-20 mA HART
  • RTD
  • Thermocouple / mV
  • AI 0-10V DC Isolated
  • AO 4-20 mA HART
  • DI NAMUR
  • DI 24V DC low-side sense (dry contact)
  • DI 24V DC Isolated
  • DO 24V DC High Side
  • DO 100mA Energy Limited
  • DO 24V DC Isolated
  • 24V DC Power
  • DI 120V AC Isolated
  • DI 120V AC Isolated Plus
  • DI 230V AC Isolated
  • DO V AC Isolated