DeltaV™ S-series IS Electronic Marshalling

Focus on what needs to be done rather than how

DeltaV™ S-series IS Electronic Marshalling

DeltaV™ S-series IS Electronic Marshalling

DeltaV™ S-series IS Electronic Marshalling

DeltaV™ S-series IS Electronic Marshalling

DeltaV™ S-series IS Electronic Marshalling
DeltaV™ S-series IS Electronic Marshalling
    • DeltaV™ S-series IS Electronic Marshalling

    • DeltaV™ S-series Electronic Marshalling delivers a new level of control system I/O performance with unprecedented flexibility and ease of use. The addition of Intrinsically Safe (IS) CHARMs provides significant savings in system design, installation cost and ease of maintenance expected with Electronic Marshalling, with the added safety for field wiring to hazardous areas.

About Us DeltaV™ S-series IS Electronic Marshalling

  • Overview
  • Specification
  • Documents

Overviews

   
     
 

DeltaV™ S-series Electronic Marshalling delivers a new level of control system I/O performance with unprecedented flexibility and ease of use. The addition of Intrinsically Safe (IS) CHARMs provides significant savings in system design, installation cost and ease of maintenance expected with Electronic Marshalling, with the added safety for field wiring to hazardous areas. The reduced footprint and associated elimination of separate barriers and the associated inter-cabinet wiring make for a more robust installation with significant cost savings.

   

Features

   
     
   
  • Supports both conventional and IS CHARMs, providing an unprecedented flexibility in control system I/O topology
   
  • Each I/O channel has a dedicated IS CHARM that provides both signal characterization and galvanic isolation for intrinsically safe applications
   
  • Helps reduce overall system cost by eliminating internal cabinet cross wiring, reducing overall footprint, simplifying I/O channel assignments, and reducing FAT activities

 

 

  • CIOC architecture is fully redundant

 

 

  • All components of the CIOC are rated for installation in Class 1/Div 2 or Zone 2 hazardous locations

 

 

  • Designed for ease of use, both in physical installation and its software tools

Specifications

   
     

Number of I/O Channels

 

96 Channels, Individually defined signal types

Number of I/O Clients

 

4 (Controllers)

Number of CIOC's per Controller

 

16

Number of CIOC's per system

 

300

I/O update rates

 

50ms, 100ms, 250ms, 500ms

Operating Temperature

 

40 to 70 °C (-40 to 158 °F)

Storage Temperature

 

-40 to 85 °C (-40 to 185 °F)

Relative Humidity

 

5 to 95% , non-condensing

Shock

 

10 g½-sine wave for 11 ms

Vibration

 

1 mm peak-to-peak from 5 to 13.2 Hz; 0.7 g from 13.2 to 150 Hz

Electronic Marshalling hardware

 

  • CHARM I/O Carrier (DIN rail mounted and supports redundant pair of CHARM I/O Cards, redundant 24V DC power connectivity, and redundant Ethernet
  • communication modules)
  • CHARM I/O Card (provides communication between CHARMs and the Ethernet I/O network to S-series controllers)
  • IS CHARM Baseplate (DIN rail mounted with interleaving power and bus connectors. Supports 12 IS CHARMs and their terminal blocks)
  • IS CHARM Terminal Block (removable terminal block providing terminal connections to field wiring and physical latch for IS CHARM)
  • IS CHARMs (Characterization Module for each field signal. Provides galvanic isolation, fault isolation and basic analog to digital conversion to the redundant communication bus)
  • Labeling features for baseplate and channel identification
  • Cable Extenders that provide flexibility in carrier mounting
  • I/O bus termination (provides bus terminations for redundant I/O bus)

Charm types

 

  • IS AI 4-20 mA HART
  • IS RTD
  • IS Thermocouple / mV
  • IS AO 4-20 mA HART
  • IS DI NAMUR
  • IS DO 45 mA DI 24V DC low-side sense (dry contact)

 